3-2 I/O Communication
3-13
3
Communicating with the SK-1000 Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
5-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
Rewrite setting value
Sensor amplifier ID numbers 01 to 08 are assigned to bits 0 to 7, respectively.
For details of communication methods, see "Rewriting a setting value of a sensor
amplifier" (page 3-19).
3-output mode
OUT area
m: The first device number assigned to the DL-DN1
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+5 Request to change BANK
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+6 Select BANK number
Specifies a new BANK number
(2-byte unsigned integer; range: 0-3).
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+11 BANK change complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+12 BANK change error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+3
Request to rewrite HI set-
ting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+4 to 5
HI setting value (BANK 0)
HI setting value to be rewritten
(4-byte signed integer)
m+6
Request to rewrite LO set-
ting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+7 to 8
LO setting value (BANK 0)
LO setting value to be rewritten
(4-byte signed integer)
Komentáře k této Příručce