Keyence DL-DN1 Uživatelský manuál Strana 40

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 76
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 39
3-2 I/O Communication
3-14
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
3
Communicating with the SK-1000 Series
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.
5-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+7
Setting-value rewrite error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+8
HI setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+9
LO setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+5
Request to rewrite HI set-
ting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+6 to 7
HI setting value (BANK 0)
HI setting value to be rewritten
(4-byte signed integer)
m+8
Request to rewrite LO set-
ting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+9 to 10
LO setting value (BANK 0)
LO setting value to be rewritten
(4-byte signed integer)
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+11
Setting-value rewrite error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+12
HI setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+13
LO setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09