2-7
2
Connection and Configuration
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
2-2
Wiring
This section describes how to wire the DL-DN1.
Refer also to the DeviceNet Installation Manual published by ODVA.
Turn off the power before wiring.
Use the following procedure to connect the DL-DN1 to the DeviceNet.

Recommended cables
For connection between the DL-DN1 and the DeviceNet, use a dedicated DeviceNet
cable conforming to the DeviceNet specifications or a dedicated flat cable.
Do not use non-dedicated cables, as this may inhibit proper commu-
nication.

Trimming the cable
1
Strip the cable sheath.
Strip approximately 70 mm of cable sheath.
Make sure that the bare part of the shield braid is 6 mm or shorter.
Point
Connecting to the DeviceNet
Point
6 mm or shorter
Approx. 70 mm
Shield braid
Sheath