3-6 DP-V1 Service
3-32
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
58 Waveform registration result DINT R
0: Currently requesting
1: Successfully completed
2:
Standard waveform registration
error 1 (received light shortage)
3:
Standard waveform registration
error 2 (extraneous light)
4:
Standard waveform registration
error 3 (wrong combination)
5: Light receiver EEPROM error
6:
Standard waveform registration
error 4 (abnormal waveform)
7: Other error
59 Reserved for system
60
Tolerance tuning/2 point
tuning result
*13 DINT R
0: Currently requesting
1: Successfully completed
2: Unexecutable
61 Calibration execution result *14 DINT R
0: Currently requesting
1: Successfully completed
2: Terminated with abnormal
span value
3: Terminated with abnormal
offset value
4: Terminated with abnormal
span/offset value
62 to 63 Reserved for system
64 Group2 Entry count DINT R 24
65 Bank 0 HIGH setting *15 DINT R +08.000 -99.999 to +99.999
66 Bank 0 LOW setting *15 DINT R +02.000 -99.999 to +99.999
67 Shift target value (BANK 0) *15 DINT R 00.000 -99.999 to +99.999
68 Sensitivity setting (BANK 0) DINT R 1
0: Low sensitivity mode
1: Standard mode
2: High sensitivity mode
3: User defined
69 User binarize level (Bank 0) DINT R 25 10 to 90
70 User filter value (Bank 0) DINT R 09 03 to 50
71 HIGH setting value (BANK 1) *15 DINT R +08.000 -99.999 to +99.999
72 LOW setting value (BANK 1) *15 DINT R +02.000 -99.999 to +99.999
73 Shift target value (BANK 1) *15 DINT R 00.000 -99.999 to +99.999
74 Sensitivity setting (BANK 1) DINT R 1
0: Low sensitivity mode
1: Standard mode
2: High sensitivity mode
3: User defined
75 User binarize level (Bank 1) DINT R 25 10 to 90
76 User filter value (Bank 1) DINT R 09 03 to 50
77 HIGH setting value (BANK 2) *15 DINT R +08.000 -99.999 to +99.999
78 LOW setting value (BANK 2) *15 DINT R +02.000 -99.999 to +99.999
79 Shift target value (BANK 2) *15 DINT R 00.000 -99.999 to +99.999
80 Sensitivity setting (BANK 2) DINT R 1
0: Low sensitivity mode
1: Standard mode
2: High sensitivity mode
3: User defined
81 User binarize level (Bank 2) DINT R 25 10 to 90
82 User filter value (Bank 2) DINT R 09 03 to 50
83 HIGH setting value (BANK 3) *15 DINT R +08.000 -99.999 to +99.999
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value