- IV Series Users Manual (Field Network) -
PROFINET communication specications and functions in the IV series
Overview of the PROFINET communication functions in the IV series
The following shows the list of functions that can be used to control the IV series in the PROFINET
communication.
Function Content
Trigger input Executes a trigger input for the sensor.
Program switching Executes a program switching for the sensor.
External master registration Executes an external master registration for the sensor.
Error clear input Executes an error clear.
Read out status Allows you to check the unit status (Imaging, RUN, BUSY, Error).
Read overall status result Reads out the overall status result.
Read judgment processing time Reads out the processing time of the judgment.
Read each tool’s status result Read each tool’s status result
Read statistics information
“Reads out the number of triggers issued that generated a trigger
error and the number of trigger errors.
If you are switching programs using the EtherNet/IP communication, set the [Switching method] option
to [Monitor/PC]. For details of the setting, refer to the “IV Series User’s Manual (Monitor / Software)”.
If the external master registration will be executed using the PROFINET communication, set the [Write
to ROM at external master reg.] option to [No]. For details of the setting, refer to the “IV Series User’s
Manual (Monitor / Software)”.
4
PROFINET