1
Vision Sensor
IV Series Setting Guide
Monitor Display
Menu OFF
Menu ON
(1) Title
Displays the device name, the program number and the program
name.
(2) Tool name
Displays the tool number and the tool name of the tool selected. The
selected tool can be switched.
(3) Brightness correction range
When the Brightness correction is set, the range will be displayed
with a blue frame.
(4) Tool window
Displays the tool window which has been set.
(5) Search Window
If the search window of the tool is set, the range will be displayed
with a light blue frame.
(6) [MENU] button
Changes the screen to the Menu ON screen.
(7) [OFF] button
Changes the screen to the Menu OFF screen.
(8) Status gauge
Displays the result (OK/NG) of the tool selected.
(9) OK/NG display
Displays the total status result.
(10) Processing time
Displays the time from receiving a trigger until the result is output.
(11) [Image Type] display
Displays the situation of the screen. Run mode or Test mode.
(12) [Trig] button
Displayed when the external trigger is set. When this button is
touched, a trigger signal is sent to the sensor.
(13) [Zoom] button
Changes the display to full screen mode and makes it possible to
enlarge the image.
(14) [View] button
Displays the menu to select how to show the tools and the analyze
screen.
(15) [Monitor settings] button
Displays the monitor screen.
(16) [Sensor Image Memory] button
Displays the Sensor Image Memory screen.
(17) [USB memory] button
Displays the USB memory screen.
(18) [Sensor setup] button
Stops the running mode and displays the Sensor setup menu
screen.
462GB
(8) (9)
(1)
(2)
(3)
(4)
(5)
(6)
(10)
(11)
(1)
(2)
(3)
(4)
(5)
(7)
(8) (9)
(10)
(11)
(12)
(13)
(14)
(18) (17)(16) (15)
Status OK (green) Status NG (red)
Threshold Matching rate
Zobrazit stránku 0
1 2 3 4 5 6

Shrnutí obsahu

Strany 1 - IV Series Setting Guide

1 Vision Sensor IV Series Setting Guide Monitor Display  Menu OFF  Menu ON (1) Title Displays the

Strany 2

2 Operation for initial start-up 1. Turn on the power of the monitor. 2. Select the language. 3. Set the current d

Strany 3

3 3. Touch the [OK] button. 4. Touch the [Auto Brightness Adjustment] button. 5. Touch the [OK] button. 6. Touch the [Focus Adjustment] button.

Strany 4

4 5. After the setting is completed, touch the [OK] button. 6. Touch the [Limit Adjustment] button. 7. Set the threshold to judge OK and NG. 8.

Strany 5

5 11. After the setting is completed, touch the [OK] button. The display will return to the main screen for the Color Area/Area tool. 12. Touch the [

Strany 6 - 1. Touch the [RUN] button

6 Start running 1. Touch the [RUN] button. 2. Confirm that the run screen opens on the monitor. 1114-1