Keyence LS-7000 Uživatelský manuál Strana 39

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 192
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 38
2-3
2
Chapter 2 Easy Setting Guide
Measurement of Outer Diameter and Width (with Two Measuring Heads)
In the following example, two measuring heads are used to measure the average outer
diameter of an object in two directions. The measurement of the object in two directions
ensures high accuracy. The result of measurement is displayed as OUT1.
X
Y
D=
2
X+Y
Set Values
Set item
Calibration
Tolerance setting
Area setting
Output
setting
AREA
Operation
Averaging
Measuring mode
Offset
Set value
AREA 1
Head 1 DIA
Make settings if required.
A1: 0.5
A2: 0.5
Select the value according to the line speed.
Normal
No settings are required.
Head 2 DIA
No settings are required.
Set the upper and lower limit values.
AREA 2
OUT 1 OUT 2
Reference
Area Settings (Page 4-7)
Calibration Settings (Page 4-20)
Output Settings (Page 4-28)
Tolerance Settings (Page 4-50)
Measures the outer diam-
eter in two directions.