Communication Response Time
DRQ input
The data read in response to a DRQ input is the buffered data that DL-RS1A periodically retrieves
from the sensor amplifiers.
Therefore, the latest data detected by the sensors can only be read after T2 (DL-RS1A data
processing time) where DL-RS1A retrieves data from the sensor amplifiers.
Time chart
SW command and AW command
The SW and AW commands are write commands.
Time chart
Sensor amplifier
DL-RS1A
T1
T2
DRQ input
T5
T4
Detection
2 ms min.
T1: Sensor amplifier response time (Refer to the instruction manual of the sensor amplifier.)
T2: DL-RS1A data processing time
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A
* For the specific values (times) of T2 to T5, refer to
"Time Frames of Communication Response Time" (page 17).
External device
DL-RS1A
T5
T3
T4
Sensor amplifier
T6
T3: Command format send time from external device
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A
T6: Sensor amplifier setting change time
* For the specific values (times) of T3 to T6, refer to
"Time Frames of Communication Response Time" (page 17).
Communication Response Time
Time Frames of Communication Response Time
This section describes the communication time frames (T2 to T6).
The maximum time required is shown for each time frame. However, depending on
the actual environment, it may require more time.
T2 (DL-RS1A data processing time)
T3 (Command send time from external device)
Refer to the manual supplied with the external device connected to DL-RS1A.
T4 (DL-RS1A command processing time)
The processing time varies according to the command sent from the external device.
z Read commands
z Write commands
Reference
Number of connected
sensor amplifiers
Data processing time (T2)
IB Series
17 ms
29 ms
313 ms
415 ms
Communication command
Number of connected
sensor amplifiers
Command processing time (T4)
IB Series
SR
112 ms
213 ms
315 ms
416 ms
M0/MS/DRQ input
1 to 4
4 ms
Communication command
Number of connected
sensor amplifiers
Command processing time (T4)
IB Series
SW
121 ms
225 ms
330 ms
434 ms
AW
157 ms
259 ms
360 ms
461 ms