4
Settings for Advanced Functions
4-39
- Digital Fiber Sensor FS-N10 Series User's Manual -
4-7
Settings Save/Recall
The current setting value and advanced function settings can be saved in the sensor
amplifier.
"Settings for Advanced Functions" (page 4-1)
Executing a custom save will override the previously saved settings
with the current settings.
1
Press and hold the [SET] and [PRE-
SET] buttons simultaneously for 3
seconds or more.
The "rSt" display flashes.
2
Press the button to display
"SAvE", and then press the [MODE]
button
3
Press the button to display "YES",
and then press the [MODE] button.
After the settings are saved, the screen
displays "oK", which is then replaced with
the current received light intensity.