5
Specifications
5-2
- Digital Fiber Sensor FS-N10 Series User's Manual -
5-1
Specifications
*1 For M8 and e-CON connector types, cable length must be 30 m or less.
*2 Increased by 100 mW (4.0 mA) for HIGH SPEED mode.
*3 One or two units connected: -20 to +55 °C; 3 to 10 units connected: -20 to +50 °C,
11 to 16 units connected: -20 to +45 °C. When using 2-output type, one unit is counted as two units.
All temperature specifications are for when the unit is mounted on a DIN rail; and installed on metal frame.
1-Output Type
Type 1-Output Type
Input/Output configuration
Cables
M8 connector
*1
e-CON connector
*1
Main unit/Expansion unit Main unit Expansion unit Main unit Expansion unit Main unit Expansion unit
Models NPN FS-N11N FS-N12N FS-N11CN FS-N12CN FS-N11EN FS-N12EN
PNPFS-N11P FS-N12P FS-N11CP FS-N12CP - -
Number of
input/out-
put
Control output 1-output1-output1-output1-output1-output1-output
Monitor output
(1-5V)
------
External input- -1-input1-input1-inpu t1-input
Light source LED Red 4-element LED (Wavelength: 630 nm)
Response time 50us(HIGH SPEED)/250us(FINE)/500us(TURBO)/1ms(SUPER)/4ms(ULTRA)/16ms(MEGA)
Output toggle Light-ON/Dark-ON toggle
Timer functions Timer OFF/OFF delay/ON delay/One shot
Input/Out-
put specifi-
cations
Control output
(NPN)
NPN open collector 24 V or less, maximum 100 mA or less (stand-alone)/20 mA or less (multiple
connections)
Residual voltage: 1V or less
Control output
(PNP)
PNP open collector 24 V or less, maximum 100 mA or less (stand-alone used)/20 mA or less
(multiple connections)
Residual voltage: 1V or less
External inputInput time: 2 ms (ON) / 20 ms(OFF) or over. 25 ms(ON/OFF) only when toggled to external
calibration input
Expansion units Up to 16 units can be connected (total connection of 17 units including the main unit); 2-output
type is treated as 2 units, however.
Protection circuit Protection against reverse power connection, output overcurrent and output surge
Number of interference preven-
tion units
Up to 16 units can be connected, but may differ depending on the power mode.
0 for HIGH SPEED; 4 for FINE and 8 for TURBO/SUPER/ULTRA/MEGA
(These numbers double when "Double" is selected.)
Rating Supply voltage 12 - 24 VDC +/- 10%, ripple (P-P) 10% or less
Power consumption
(NPN output type)
Normal: 900 mW or less (36 mA or less at 24 VDC; 48 mA or less at 12 VDC)
*2
ECO ON (All): 800 mW or less (32 mA or less at 24 VDC; 39 mA or less at 12 VDC)
*2
ECO Full: 470 mW or less (19 mA or less at 24 VDC; 23 mA or less at 12 VDC)
Power consumption
(PNP output type)
Normal: 950 mW or less (39 mA or less at 24 VDC; 52mA or less at 12 VDC)
*2
ECO ON (All): 850 mW or less (35mA or less at 24 VDC; 44 mA or less at 12 VDC)
*2
ECO Full: 520 mW or less (21mA or less at 24 VDC; 26mA or less at 12 VDC)
Environ-
ment resis-
tance
Operating ambient
luminance
Incandescent lamp: 20,000 lx or less; solar light: 30,000 lx or less
Operating ambient
temperature
-20 °C to +55 °C (no freezing)
*3
Operating ambient
humidity
35 to 85%RH (no condensation)
Vibration resistance 10 to 55 Hz Compound amplitude 1.5 mm, 2 hours for each of X, Y and Z axes
Shock resistance
500m/s
2
, 3 times for each of X, Y and Z axes
Case material Both main unit and cover material: Polycarbonate
Case dimensions H30.3mm×W9.8mm×L71.8mm
Mass Approx. 75 g Approx. 45g Approx. 22g Approx. 22g Approx. 22g Approx. 22g