Keyence LK-G Series Uživatelský manuál Strana 144

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 198
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 143
5-14
5
LK-G-M-NO5-E
5 RS-232C
Command details
This section describes the details of the incoming commands and the response com-
mands that are sent when the incoming commands are properly processed.
Display panel switch
Switches the content displayed on the display panel.
Tolerance setting
Sets the tolerance.
* The head of the hysteresis is not a character but "0" (zero).
Refer to "
Outline of the command format
" (page 5-5) for the error response command.
Refer to "Timing Chart" (page 5-21) for the response delay time of the response
command.
Incoming command
Response command
CR
D C
D C ,
CR
a
OUT number
0 : OUT1
+
OUT2
1 : OUT1
2 : OUT2
Incoming command
Response command
S
ML
W
,
S
W , L M , a , f f f f f f f , f f f f f f f ,
0 f f f f f f
CR
CR
Upper limit
Setting value format
Hysteresis
Setting value format
Lower limit
Setting value format
OUT number
1 : OUT1
2 : OUT2
Zobrazit stránku 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 197 198

Komentáře k této Příručce

Žádné komentáře