Keyence Visual KV Series Uživatelský manuál Strana 193

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 444
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 192
5.2 Module/Unit Specifications
KV-300
KV-10/80
1
5
Chapter 5 KV-300 Hardware
1-169
5.2.2 Wiring: KV-U5 DC Power Distribution Module
Parts and functions
1. POWER indicator (green)
2. Power input terminal
(M3 screws) for 24 VDC
No. Name Function
1 POWER indicator (green) Lights when DC power is supplied to the power
input terminals 2.
2 Power input terminals For 24 VDC power supply
(M3 screws)
Do not connect an AC power supply to the power input terminals; doing so
will damage the KV-U5.
Note 1: Supply power of at least 1.5 times the input capacity to the power input
terminal.
Note 2: Install the KV-U5 in the leftmost position of the system. Install the KV-300
CPU immediately to the right of the KV-U5.
CAUTION
KVHKA Chap 05.p65 08.3.11, 11:14 AM169