8.2 Configuration
KV-300 Series Only
KV-300
KV-10/80
Chapter 8 KV-AN6 Analog I/O Module
1-313
1
8
8.2 Configuration
8.2.1 Parts and Functions
±5V
±10V
±5V ±10V 0~20mA
CH4
D
/
A
CH5
CH1
D
/
A
CH2
CH0
CH3
2
4
1
3
5
Note 1: To remove the terminal block, refer to page 1-316.
Note 2: To use analog current output (4 to 20 ms), a terminal separated from the
analog voltage output terminals is required.
No. Part name Function
1 READY indicator Lights when power (24 VDC) is supplied to the
KV-AN6.
2 Analog I/O terminal block Removable terminal block for analog input
signals (4 ch.) and analog output signals (2 ch.)
3 Terminal block lock bar Lock mechanism used to lock/release the
analog I/O terminal block
4 Input range selection switch Selects the analog input range for A/D conver
sion. Provided for each channel.
(White represents the switch position.)
5 Output range selection switch Selects the analog output range for D/A conver
sion. Provided for each channel.
(White represents the switch position.)
±5V
±10V
0 to 20mA
±5V ±10V