Keyence Visual KV Series Uživatelský manuál Strana 88

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 444
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 87
Chapter 2 System Installation
1-64
2
Visual KV
Series
2.1 Installation Environment
This section describes cautions with the environment in which each unit is installed
and the installation position inside the panel.
2.1.1 Installation Environment
Never install a unit in the following locations:
Locations exposed to direct sunlight
Locations whose ambient temperature is outside the allowable range of 0 to
+50°C
Locations whose ambient humidity is outside the allowable range of 35 to 85%
RH
Locations subject to drastic temperature change where condensation may occur
Locations with corrosive or flammable gases
Locations with excessive dust, salt, iron powder, or soot
Locations subject to direct vibrations and impacts
Locations subject to splashes of water, oil, chemicals, etc.
Locations where a strong magnetic or electrical field is generated
Units are made of synthetic resin. If the unit surface touches a solvent with a
strong dissolving force, it could melt. Keep such solvents away from the units.
2.1 Installation Environment
CAUTION
KVHKA Chap 02.p65 08.3.11, 11:11 AM64
Zobrazit stránku 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 443 444

Komentáře k této Příručce

Žádné komentáře