6.3 Functions
Chapter 6 Handheld Programmer
1-225
1
6
When the KV is write-disabled, the preset value cannot be changed.
Any preset value of the timer/counter which is not set on the program cannot be
changed.
TMH or TMS is specified using TMR.UDC is specified using CTR.
The preset value in the source program is also changed.
*1. In the case where the counter (C) input is ON and the up-down counter (UDC)
reset input is OFF:
*2. In the case contrary to the above *1:
Key operation
Basic operation
Example of operation (In the PROGRAM mode)
When the TIMER/COUNTER SETTING CHANGE function is accessed, pressing
@
#, $
alternates between the decimal display and hexadecimal display.
CTC
ENT
R-SRCH
FNC
Timer (or counter) No.
ENT
R-SRCH
ENT
R-SRCH
Preset value
RES
0
LD
7
CTR
(C)
TMR
(T)
Key operation Display Description
RUN
Display arbitrary line.
LD 00000
T/C SET-V #00020 Access TIMER/COUNTER SETTING
TMR000 CHANGE [CHG: T/C SET-V] function.
T/C SET-V #00100 Specify CTR001. Then preset value of
CTR001 #00000 CTR001 is displayed.
T/C SET-V #00100 Enter desired value as new current
CTR001 #00200 value. (200)
T/C SET-V #00200
Preset value has been changed.
CTR001
00000
Return to initial display.
LD 00000
FNC
ENT
R-SRCH
CLEAR
SET
1
RES
0
ENT
R-SRCH
ENT
R-SRCH
RES
0
ANL
2
LD
7
CTR
(C)
AND
8
KVHKA Chap 06_3&4&5.p65 08.3.11, 11:17 AM225